Multicore XLPE Insulated, Steel Wire Armored, Flame Retardant Low Smoke PVC Sheathed (CU/XLPE/SWA/FRLS PVC)

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502-1
  • Test
    IEC 60332-1-2

Scope

This specification covers XLPE insulated, circular shaped, multicore armoured cables. Rated at 0.6/1 kV and compliant with IEC 60502-1, these cables are ideal for indoor, outdoor, duct, and direct burial applications especially where mechanical stress, fire safety, and low smoke emission are critical.

Construction

2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.

2.2 Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.

2.3 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of flame retardant thermoplastic material.

2.4 Armour
Galvanized round wires completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.

2.5 Sheath
Flame retardant PVC compound conforming to the applicable requirements of IEC 60502-1.

2.6 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products

Application

 These cables are intended for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are presen

They are designed to enhance safety in areas where fire risk and smoke emission are critical concerns.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
-
Conductor material
-
Insulation
-
Material of bedding
-
Outer sheath
-

Dimensional characteristics

Dimensional characteristics

Approximate weight
- kg/km
Diameter over insulation
- mm
Nominal Diameter under armour
- mm
Nominal conductor diameter
- mm
Nominal insulation thickness
- mm
Nominal outer diameter
- mm
Sheath thickness
- mm

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
- Ohm/km
Perm current rating in air 30°C
- A
Permissible current rating buried 20°C
- A
Rated Voltage Uo/U (Um)
-

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
-

Usage characteristics

Usage characteristics

Bending factor when installed
- (xD)
Flame retardant
-
Maximum operating temperature
- °C
Operating temperature, range
- °C
Short-circuit max. conductor temperature
- °C
U.V resistance
-

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close